Int J Cardiovasc Imaging ; 36(10): 2007-2015, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32472299

RESUMO

To evaluate the accuracy of 3D models of the aortic-root generated from non-contrast cardiac magnetic resonance (CMR). Data were retrospectively collected from 30 consecutive patients who underwent surgical aortic valve replacement and had available records of both intra-operative assessment and pre-surgery annulus assessment by cardiovascular computed tomography (CCT) and CMR. The 3D models were independently segmented, modelled and printed by two blinded "manufacturers". The measurements on the models were carried out by two cardiac surgeons with Hegar dilator. Data were analyzed with non-parametric tests. There was no significant intra- or inter-observer variability (p ≥ 0.13). The agreement between the diameter of the 3D model derived from CMR images and either the anatomical reference of the intraoperative measurement (p = 0.10, r = 0.97) or the radiological reference of the 3D model generated from CCT (p = 0.71, r = 0.92) was very good. The process of segmentation plus the post-processing was about 17 ± 2 min for a model created by CMR, significantly higher than a model created from CCT (7 ± 2 min; p < 0.001). The printing time for a single model did not differ between the two modalities (p = 0.61) and was less than 60 min. The cost for a single model was approximately 0.5 €. 3D models generated from non-contrast CMR performed well when compared to the anatomical reference standard and are comparable to the pair CCT derived models.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores , Impressão Tridimensional , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter , Fluxo de Trabalho
2.
Clin Neuroradiol ; 30(1): 67-76, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30426172

RESUMO

PURPOSE: The acute distal intracranial occlusion of the internal carotid artery (ICA) is a very complex heterogeneous pathology, characterized by various patterns. Aim of this work is to identify the different types and propose a classification. METHODS: Among the patients admitted for stroke in the anterior circulation from august 2014 to October 2017, 46 (25%) presented with intracranial distal carotid artery occlusion. The mean age of the patients was 71 (SD 13.7), 65,2% female. The protocol included general and specific neurological examinations, CT, CT-Angiography with multiphase CTA, followed by Angiography. The occlusion was treated by aspiration device alone or associated with stent-retriever. NIHSS at the admission, at discharge and modified ranking Scale (mRS) at four months were examined. RESULTS: The occlusions presented with various patterns. Depending on its site (located at the distal ICA bifurcation or more proximal at the level of the ophthalmic segment of ICA, with or without extent to ICA bifurcation) taking also into account the various involvement of the cerebral vessels and anatomic variations of Circle of Willis, three groups of occlusion types could be identified (T1, T2 and T3). The collateral circulation, and the possibilities of the endovascular revascularization important for the final outcome, were clearly connected with the type of occlusion. NIHSS at admission was 19.1 (Range from 8 to 30, SD 4.4). Good outcome defined as mRS 0-2 at for months was obtained in 17 patients (37%). CONCLUSIONS: The proposed classification reproduces more precisely the complexity and heterogeneity of this pathology, being useful in the diagnosis and treatment of these patients.


Assuntos
Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/diagnóstico por imagem , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/fisiopatologia , Doenças das Artérias Carótidas/fisiopatologia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/fisiopatologia , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/fisiopatologia
3.
J Cardiovasc Comput Tomogr ; 12(5): 391-397, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29857953

RESUMO

BACKGROUND: to determine reliability and reproducibility of measurements of aortic annulus in 3D models printed from cardiovascular computed tomography (CCT) images. METHODS: Retrospective study on the records of 20 patients who underwent aortic valve replacement (AVR) with pre-surgery annulus assessment by CCT and intra-operative sizing by Hegar dilators (IOS). 3D models were fabricated by fused deposition modelling of thermoplastic polyurethane filaments. For each patient, two 3D models were independently segmented, modelled and printed by two blinded "manufacturers": a radiologist and a radiology technician. Two blinded cardiac surgeons performed the annulus diameter measurements by Hegar dilators on the two sets of models. Matched data from different measurements were analyzed with Wilcoxon test, Bland-Altmann plot and within-subject ANOVA. RESULTS: No significant differences were found among the measurements made by each cardiac surgeon on the same 3D model (p = 0.48) or on the 3D models printed by different manufacturers (p = 0.25); also, no intraobserver variability (p = 0.46). The annulus diameter measured on 3D models showed good agreement with the reference CCT measurement (p = 0.68) and IOH sizing (p = 0.11). Time and cost per model were: model creation ∼10-15 min; printing time ∼60 min; post-processing ∼5min; material cost ∼1€. CONCLUSION: 3D printing of aortic annulus can offer reliable, not expensive patient-specific information to be used in the pre-operative planning of AVR or transcatheter aortic valve implantation (TAVI).


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Dados Preliminares , Desenho de Prótese , Estudos Retrospectivos
4.
Radiother Oncol ; 127(3): 481-486, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29729845

RESUMO

BACKGROUND AND PURPOSE: Inadvertent heart and coronary arteries (CA) irradiation may increase the risk of coronary artery disease (CAD) in patients receiving thoracic irradiation. To date, the entity of cardiac-related CA displacement and the possible margins to be used for planning organs at risk volume (PRV) have been poorly described. Aim of this study was to quantify CA displacement and to estimate PRV through the use of ECG-gated computed tomography (CT) scans. MATERIAL AND METHODS: Eight patients received an ECG-gated intravenous contrast enhanced CT for non-cancer related reasons. Nine data sets were reconstructed over the entire R-R cycle with a dedicated retrospective algorithm and the following structures were delineated: Left main trunk (LM), left anterior descending (LAD), left circumflex (CX) and right coronary artery (RCA). CA displacements across the different cardiac phases were evaluated in left-right (X), cranio-caudal (Y) and anteroposterior (Z) directions using the McKenzie-van Herk formula (1.3 * Σ + 0.5 * σ). RESULTS: The following CA displacements were found in X, Y and Z coordinates: 3.6, 2.7 and 2.7 mm for LMT, respectively; 2.6, 5.0 and 6.8 mm for LAD, respectively; 3.5, 4.5 and 3.7 mm for CX, respectively; 3.6, 4.6 and 6.9 mm for RCA, respectively. Based on the mean displacements, we created a PRV of 3 mm for LM, 4 mm for CX and 5 mm for LAD and RCA. CONCLUSION: CA showed relevant displacements over the heart cycle, suggesting the need for a specific PRV margin to accurately estimate the dose received by these structures and optimize the planning process.


Assuntos
Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/métodos , Coração/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Doença da Artéria Coronariana , Vasos Coronários/anatomia & histologia , Vasos Coronários/efeitos da radiação , Coração/anatomia & histologia , Coração/efeitos da radiação , Humanos , Mediastino/anatomia & histologia , Mediastino/diagnóstico por imagem , Mediastino/efeitos da radiação , Movimento (Física) , Órgãos em Risco/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
5.
Int J Cardiovasc Imaging ; 32(8): 1255-63, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27117264

RESUMO

To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland-Altman (BA) plots, Wilcoxon's and Friedman's tests; trends were explored with scatter plots. Categorical variables were studied with Fisher's exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Cuidados Intraoperatórios , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Radiol Med ; 121(4): 291-300, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26676837

RESUMO

OBJECTIVE: The purpose of this study was to optimize an aorta angiographic CT protocol, by investigating the best combination of tube current modulation, iterative algorithm strength and kV reduction. MATERIALS AND METHODS: Anthropomorphic phantoms of three sizes were imaged by CT with different values of noise index, of iterative algorithm ASIR percentages and kV in the range 80-120. Quantitative noise and contrast noise ratios were evaluated at different phantom locations. Three radiologists assessed the subjective image quality by comparing the image series with the one acquired with the reference protocol (120 kV, slice thickness 0.625, noise index 28, ASIR 40 %). RESULTS: Although the highest CNR values were obtained for the 80 kV acquisitions, qualitative scores were higher for 100 and 120 kV at the same noise index. An optimized protocol was established with a NI of 39.2, ASIR 60%, 100 kV for small- and medium-sized patients and 120 kV for large-sized patients, with a dose reduction of 47%. CONCLUSION: When different dose reduction parameters are available, anthropomorphic phantoms of different sizes help to find the optimal combination. For aorta studies, 100 kV with relative high values of noise indexes and iterative levels provides the best balance between dose reduction and image quality.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Imagens de Fantasmas
7.
Atherosclerosis ; 240(1): 197-204, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25797313

RESUMO

INTRODUCTION: Asymptomatic patients with human immunodeficiency virus (HIV) infection are at increased risk of vascular disease. Whether asymptomatic HIV patients have increased prevalence or structural differences in coronary artery plaques is not clear. METHODS: Pubmed, Cochrane and Google Scholar were searched for articles evaluating asymptomatic HIV patients evaluated with coronary computed tomography. The prevalence of coronary stenosis (defined as >30% and >50%), of calcified coronary plaques (CCP) viewed as more 'stable' plaques, and of non-calcified coronary plaques (NCP) viewed as more 'vulnerable' plaques were the end points of interest. RESULTS: 9 studies with 1229 HIV patients and 1029 controls were included. No significant differences were detected about baseline cardiovascular risk profile. The prevalence of significant coronary stenosis>30% or >50% did not differ between HIV+ and HIV- patients (42% [37-44] and 46% [35-52] with an Odds Ratio [OR] of 1.38 [0.86-2.20] for >30% stenosis) and (15% [9-21] and 14% [7-22] with an OR of 1.11 [0.81-1.52]), respectively. The prevalence of calcified coronary plaques (CCP) (31% [24-32] and 21% [14-30] with an OR of 1.17 [0.63-2.16]) also did not differ among HIV+ and HIV- patients. On the contrary rates of NCP were >3-fold higher in HIV-positive patients [58% (48-60) and 17% (14-27) with an OR of 3.26 (1-30-8.18)], with an inverse relationship with CD4 cell count at meta-regression (Beta -0.20 [-0.35-0.18], p 0.04). CONCLUSION: Asymptomatic HIV patients present a similar burden of coronary stenosis and calcified coronary artery plaques but significantly higher rates of non-calcific coronary plaques at computed tomography. The association between HIV infection, reduced CD4 cell counts and higher prevalence on non-calcific coronary artery plaques may shed light into the pathogenesis in HIV-associated coronary artery disease, stressing the importance of primary prevention in this population.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Infecções por HIV/tratamento farmacológico , Placa Aterosclerótica , Terapia Antirretroviral de Alta Atividade , Doenças Assintomáticas , Contagem de Linfócito CD4 , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/epidemiologia , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Humanos , Incidência , Razão de Chances , Valor Preditivo dos Testes , Prevalência , Medição de Risco , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia
11.
J Clin Endocrinol Metab ; 93(4): 1366-71, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18198224

RESUMO

CONTEXT: In patients with primary aldosteronism (PA), it is fundamental to distinguish between subtypes that benefit from different therapies. Computed tomography (CT) scans lack sensitivity and specificity and must be followed by adrenal venous sampling (AVS). Because AVS is not widely available, a list of clinical criteria that indicate the presence of an aldosterone-producing adenoma (APA) has been suggested. OBJECTIVE AND DESIGN: The objective of the study was to test the sensitivity and specificity of the last generation CT scans, test prospectively the usefulness of clinical criteria in the diagnosis of APA, and develop a flow chart to be used when AVS is not easily available. SETTING: Hypertensive patients referred to our hypertension unit were included in our study. PATIENTS: Seventy-one patients with confirmed PA participated in our study. INTERVENTION: All patients had a CT scan and underwent AVS. MAIN OUTCOME MEASURE: Final diagnosis of APA was the main measure. RESULTS: A total of 44 and 56% of patients were diagnosed as having an APA and a bilateral adrenal hyperplasia (BAH), respectively. Twenty percent of patients with PA displayed hypokalemia. CT scans displayed a sensitivity of 0.87 and a specificity of 0.71. The posture test displayed a lower sensitivity and specificity (0.64 and 0.70, respectively). The distribution grades of hypertension were not significantly different between APA and BAH. Biochemical criteria of high probability of APA displayed a sensitivity of 0.32 and a specificity of 0.95. CONCLUSIONS: This study underlines the central role of AVS in the subtype diagnosis of PA. The use of the clinical criteria to distinguish between APA and BAH did not display a satisfactory diagnostic power.


Assuntos
Glândulas Suprarrenais/irrigação sanguínea , Hiperaldosteronismo/diagnóstico , Tomografia Computadorizada por Raios X , Glândulas Suprarrenais/patologia , Adulto , Coleta de Amostras Sanguíneas/métodos , Diagnóstico Diferencial , Humanos , Hiperaldosteronismo/classificação , Hiperplasia , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Veias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...